Eaton 9130 Rackmount UPS

Eaton 9130 Rackmount UPS
Eaton 9130 Rackmount UPS – Product snapshot
Product rating: 700–3000 VA
Voltage 120 Vac, 208–240V
Frequency: 50/60 Hz (auto-sensing)
Configuration: Rackmount

Advanced power protection for:
• IT and networking environments
• Rack servers, networking gear
• Telecommunications, VoIP, security systems
• Medical systems
• Diagnostics and medical screening
• Patient record archives
• Manufacturing systems
• Chip fabrication
• Pharmaceutical production
• Chemical processing

TTA Compliant

Low total cost of ownership
• More real output power for dollar spent with 0.9 power factor
• Cuts energy usage and costs with >95% efficiency rating in high efficiency mode
• 3000 VA in only 2U of space saves expensive data center real estate

Hot-swappable internal batteries in only 2U
Hot-swappable internal batteries in only 2U

Add up to four EBMs for hours of runtime
Add up to four EBMs for hours of runtime

See more photos here.

Intelligent Power Software Suite
By integrating the suite with the Eaton 9130, you can:
• Seamlessly integrate with VMware’s vCenter Server™ virtualization management solution, as well as virtualization platforms such as Citrix® XenServer, Microsoft SCVMM™, Red Hat® and other Xen® open source platforms
• Initiate live migration of virtual machines (VM) to automatically and transparently migrate VMs during power disruptions to unaffected devices with systems such as VMware vMotion™ and Microsoft Live Migration
• Integrate with VMware vCenter Site Recovery Manager

Integrates with Citrix XenServer, Microsoft SCVMM, Red Hat and other Xen open source platforms

Eaton 9130 Rackmount UPS Features:
• Protects against downtime, data loss and process interruption by providing continuous, clean power
• Graphical user interface provides all critical UPS information on a single screen and enables settings control at the push of a button
• Provides up to 3000 VA in only 2U of rack space
• Offers premium performance with a 0.9 power factor and >95 percent efficiency in high efficiency mode
• Increases battery service life and system uptime with ABM® battery charging technology
• Enables prolonged runtime of essential equipment during power outages by allowing for orderly, remote shutdown of non-critical systems or processes
• Ensures data and system integrity with Intelligent Power® Manager supervisory software, which provides easy, versatile, remote monitoring and management of multiple devices
• Provides a two-year limited warranty, an extended warranty, on-site Flex and on-site PowerTrust service contracts, and a $250,000 load protection guarantee (U.S. and Canada)

Maximum availability
• ABM technology increases battery life and system uptime
• Load segments allow for selective load shedding during outages
• Optional 2U, hot-swappable extended battery modules (EBMs) extend backup runtime for hours
• Internal hot-swappable batteries can be replaced without powering down the UPS
• UPS startup on battery power
• HotSwap Maintenance Bypass (MBP) and PowerPass Distribution Modules (PPDMs) options enable the entire UPS to be serviced or replaced without powering down critical systems

UPS status and operation
• Bright front panel LCD for easy monitoring and management
• LEDs to show system status
• Optional FlexPDU adds more plug-and-play flexibility, streamlining power distribution
• Multiple options for industry-standard communications
• Intelligent Power Manager supervisory software included free of charge
• Direct monitoring via existing management systems and LANs

Communications
• A standard communication slot accepts interfaces for Web, SNMP, Modbus or serial connectivity
• Connect directly to the Ethernet network and the Internet to monitor and manage the UPS with a standard Web browser
• Monitor power conditions in real time through existing facilities or building management system
• Monitor and gracefully shut down multiple servers running various operating systems
• Receive alarm notifications from the UPS, environmental monitoring devices or security systems

Optional FlexPDU and HotSwap MBP for greater flexibility and uptime
Optional FlexPDU and HotSwap MBP for greater flexibility and uptime

Four-post rail kit included (2-post rail kit optional)
Four-post rail kit included (2-post rail kit optional)

Eaton 9130 Rackmount UPS back panel

9130 models
Catalog NumberStyle numberRating
(VA/Watts)
Input
connection1
Output receptaclesDimensions
H x W x D, in
Weight, lb
North American models: 120V, 50/60 Hz
PW9130L700R-XL2U103006447-6591700/6305-15P(6) 5-15R3.4 x 17.2 x 17.735.3
PW9130L1000R-XL2U103006448-65911000/9005-15P(6) 5-15R3.4 x 17.2 x 17.735.3
PW9130L1500R-XL2U103006449-65911500/13505-15P(6) 5-15R3.4 x 17.2 x 17.743.0
PW9130L2000R-XL2U103006450-65912000/18005-20P(6) 5-20R, (1) L5-20R3.4 x 17.2 x 23.663.9
PW9130L2500R-XL2U103006451-65912500/2250L5-30P(6) 5-20R, (1) L5-20R3.4 x 17.2 x 23.665.0
PW9130L3000R-XL2U103006452-65913000/2700L5-30P(6) 5-20R, (1) L5-20R3.4 x 17.2 x 23.665.0
PW9130L1500R-XL2UN1500 / 13505-15P(6) 5-15R3.4 (2U) x 17.3 x 16.943.0
PW9130L2000R-XL2UN2000 / 18005-20P(6) 5-20R, (1) L5-20R3.4 (2U) x 17.3 x 22.663.9
PW9130L3000R-XL2UN3000 / 2700L5-30P(6) 5-20R, (1) L5-30R3.4 (2U) x 17.3 x 22.665.0
Global models: 208V, 50/60 Hz
PW9130G3000R-XL2U103006454-65913000/2700L6-20P4(1) L6-30R, (1) L6-20R, (2) 6-20R3.4 x 17.2 x 23.665.0
PW9130G3000R-XL2UEU103006483-65913000/2700L6-20P4(8) C13, (1) C193.4 x 17.2 x 23.665.0
International models: 230V, 50/60 Hz
PW9130i1000R-XL2U103006455-65911000/900C14(6) C133.4 x 17.2 x 17.735.3
PW9130i1500R-XL2U103006456-65911500/1350C14(6) C133.4 x 17.2 x 17.743.0
PW9130i2000R-XL2U103006457-65912000/1800C14(8) C13, (1) C193.4 x 17.2 x 23.663.9
PW9130i3000R-XL2U103006463-65913000/2700C20(8) C13, (1) C193.4 x 17.2 x 23.665.0
Extended battery modules
PW9130N1000R-EBM2U5103006458-6591NANANA3.4 x 17.2 x 17.748.7
PW9130N1500R-EBM2U6103006459-6591NANANA3.4 x 17.2 x 17.762.0
PW9130N3000R-EBM2U7103006460-6591NANANA3.4 x 17.2 x 23.690.6
TAA Compliant SKUS Eaton now offers TAA compliant models for the 9130.

PowerPass Distribution Modules
Catalog NumberDescriptionInput connectionOutput receptaclesDimensions
H x W x D, in
Weight, lb
103002730-6501PPDM1-HV-US-P2 3 kVAIEC320-C208(1) L5-30R & (6) 5-20R3.5 (2U) x 17.0 x 23.920.0
103002732-6591PPDM1-HV-US-HW 3 kVA (ROHS)HardwireHardwire3.5 (2U) x 17.0 x 23.920.0
103002735-6591PPDM2-LV-US-HW 3 kVA (ROHS)HardwireHardwire3.5 (2U) x 17.0 x 23.920.0
103002739-6591PPDM1-HV-US-P1 3 kVA (ROHS)IEC320-C208(1) L14-30R & (6) 5-20R3.5 (2U) x 17.0 x 23.920.0
103002742-6501PPDM2-LV-US-P1 3 kVAL5-30P8(1) L5-30R & (6) 5-20R3.5 (2U) x 17.0 x 23.920.0
1. Input cord length is 6 ft. 2. Rack models occupy 2U of rack space and fit into 19-inch racks. 3. C14, w/detachable L6-20P. 4. C20, w/detachable L6-20P. 5. This EBM works with 700/1000 VA models, where available. 6. This EBM works with 1500 VA model. 7. This EBM works with 2000/2500/3000 VA models, where available. 8. Connection cables to the UPS are included with the PPDM; use the input cord from the UPS as input to the PPDM, except for hardwire units.Additional notes: When high voltage 9130 is used at 208V, derate power by 10% and 20% at 200V. When low voltage 9130 is used at 110V, derate power by 10% and 20% at 100V.

Battery runtimes (in minutes)
Load (VA/WattsInternal batteriesw/1 EBMw/2 EBMsw/3 EBMsWw/4 EBMs
PW9130L700R-XL2U
700/4901455102148175
525/3682077140179239
350/24532124189282414
175/12364200395552739
PW9130L1000R-XL2U
1000/700104073108149
750/5251358101152219
500/3502485172249304
250/17548190310451569
PW9130L1500R-XL2U
1500/10507346388135
1125/788114484129210
750/5251879148207267
375/26338167278475540
PW9130i1500R-XL2U
1500/10507326198128
1125/788114783126195
750/5251881143208262
375/26338171298416564
PW9130L2000R-XL2U
2000/140094586124163
1500/10501466115165225
1000/70026101185251343
500/35052197353481629
PW9130L2500R-XL2U
2500/22507315987119
1875/1688104381121154
1250/11251765120163203
625/56340145228363491
PW9130L3000R-XL2U
3000/21005254872100
2250/157583772102137
1500/10501360100165223
750/52534138228326438
PW9130G3000R-XL2U / PW9130G3000R-XL2UEU / PW9130i3000R-XL2U
3000/2100625456896
2250/15758347096130
1500/1050146292156211
750/52534130212355442
Notes: Backup times are approximate and may vary with equipment, configuration, battery age, temperature, etc.Runtimes are shown at a 0.7 power factor.

Battery runtime: You can get up to five hours of battery runtime using the internal batteries and extended battery modules.


Eaton 9130 Rackmount UPS Technical specifications1
General
User interfaceGraphical LCD with blue backlight and text in English, French, German, Russian and Spanish
LEDsFour status-indicating LEDs
TopologyTrue online, double-conversion
DiagnosticsFull system self-test
UPS bypassAutomatic bypass
DimensionsSee models table above
Rail kit4-post rail kit included with all rackmount units
EBMsShip with a 4-post rail kit
Remote Emergency Power-off (REPO)Emergency shutdown control
Electrical input
Nominal voltage120V, 208V, 220–240V
Voltage range120V: 90–138 Vac
208/230V: 160–276 Vac
Power draw of UPS700: 5.8A @120V, 3.4A @208V, 3.0A @230V
1000: 8.3A @120V, 4.8A @208V, 4.3A @230V
1500: 12.5A @120V, 7.2A @208V, 6.5A @230V
2000: 16.6A @120V, 9.6A @208V, 8.7A @230V
2500: 20.8A @208V, 10.9A @230V
3000: 14.4A @208V, 13.0A @230V
Dedicated circuit breaker rating120V:
700–1500 VA: 15A
2000 VA: 20A
2500–3000 VA: 30A
208/230V:
700–2000 VA: 10A
3000 VA: 16A
Frequency50/60 Hz
Frequency range45–65 Hz
Electrical output
Power factor0.9
On utility voltage regulation±3% of nominal
On battery voltage regulation±3% of nominal
Efficiency>95% in high-efficiency mode; >86% in online mode
Frequency regulation±3% Hz online
Load crest factor3 to 1
Voltage waveformSine wave
Load segmentsTwo configurable, individually controlled receptacles
Battery
Battery typeVRLA 12V/9 Ah (both internal and external)
Battery runtime>3 minutes with internal batteries @100% load
Battery replacementHot-swappable internal and external batteries
Start-on-batteryAllows start of UPS without utility input
Communications
Serial portRS-232 standard, for interface to power management software
USB portHID standard, for communicating with Windows 98, XP, ME and Vista computers
Relay outputCommon alarm standard
Communications slotOptional communication slots (BD Slot, Mini-Slot)
Optional Communications CardsSNMP/Web card for direct control and monitoring in SNMP-based networks, monitoring of UPS status and meters through Web browser interface Relay card for integration to industrial environment and building management systems, remote shutdown for IBM AS/400 systems
Environmental
Safety markings120/208V: UL, CUL, VCCI
230V: CE, GS
EMC markings120V: FCC Class B, EN55022 Class B (1.5 kVA and below); FCC Class A, EN55022 Class A (2.0 kVA and above) 230V: CE (per IEC/EN62040-2: Emissions, Category C1; Immunity, Category C2)
Audible noise<50 dB
Ambient operating temperature0˚C (32˚F) to +40˚C (104˚F)
Storage temperature-20˚C (-4˚F) to +40˚C (104˚F) with batteries and -25˚C (-13˚F) to +55˚C (131 ˚F) without batteries
Relative humidity5–90% non-condensing
Heat dissipation for all voltages: 208–240V and 120V
Normal Mode700 VA: 350 BTUs/hr
1000 VA: 500 BTUs/hr
1500 VA: 750 BTUs/hr
2000 VA: 838 BTUs/hr
2500 VA: 1,047 BTUs/hr
3000 VA: 1,257 BTUs/hr
Battery Mode700 VA: 554 BTUs/hr
1000 VA: 674 BTUs/hr
1500 VA: 1,011 BTUs/hr
2000 VA: 1,348 BTUs/hr
2500 VA: 1,463 BTUs/hr
3000 VA: 1,755 BTUs/hr
1 Due to continuing product improvement programs, specifications are subject to change without notice.

Eaton UPS UpgradeEaton 9130 Rackmount UPS – What’s in the box: Tower pedestals, Four-post rail kit, User manual CD, Intelligent Power Software Suite CD, Quick start guide, USB cable, RS-232 serial cable, Phillips Head screw driver, 2 IEC to IEC jumper cables (208V/230V models).

See more photos here.